Availability: | |
---|---|
Quantity: | |
24kV Solid Insulation Electrical Switchgear Ring Main Unit
Ring Main Unit
The AVR series intelligent compact solid insulation switch equipment is the company based on the development needs of smart grid, integrates "intelligent, energy saving, environmental protection, freevilled", combined with the actual situation and intelligent power grid construction requirements in combination with my country's distribution network. Secondary integration technology, developing production of independent intellectual property, domestic first intelligent permanent magnet (spring) vacuum switching equipment, integral, control, protection, communication and other functions, high intelligence. This product applies to power systems of 50Hz, 12KV, 24KV, 40.5KV, widely used in industrial and civil cable ring networks and power-on-end projects, and is the preferred equipment to ensure power grid safety, reliable, economical and efficient operation.
Model Description
Note: For more configuration, please contact us.
Use environment
Name | unit | Environmental value | |
Amazing air temperature | Maximum temperature | ℃ | +50 |
Minimum temperature | --40 | ||
Maximum temperature difference | K | 30 | |
altitude | m | ≤5000 | |
Solar radiation intensity | W / cm2 | 0.1 | |
Contamination | Ⅳ | ||
Ice thickness | mm | 10 | |
humidity | Daily relative humidity average | % | ≤100 |
Monthly relative humidity average | ≤95 | ||
Tolerate earthquake | 度 | ≤8 |
Note: Environmental parameters are exceeded in the previous table, please contact us.
Product features
Protective function | The fault current can be automatically identified, realizing the transient current speed, time-limited current speed, timing overcurrent, directional overflow, overvoltage, undercarrons, and cool load start suppression, cold load start suppression break. |
Measurement function | It can measure the three-phase current, three-phase voltage, active power, reactive power, active power, reactive power, peak / valley, power factor and frequency. |
control function | The local operation and distant control can be realized, and the fault location of the line can be automatically implemented, fault isolation and quickly restore non-fault line power supply, realize the low frequency automatic load, automatic capacitor automatic and related control functions. |
Data recording function | Information such as operation, operation, and failure can be automatically recorded. |
Intelligent function | On-line integrated analysis of the grid parameters, online monitoring of the performance parameters of the circuit breaker, online programming, can cooperate with the main station of the distribution network, implement remote control management of switching equipment, realize local, distant or hierarchical control Automation system function. |
24kV Solid Insulation Electrical Switchgear Ring Main Unit
Ring Main Unit
The AVR series intelligent compact solid insulation switch equipment is the company based on the development needs of smart grid, integrates "intelligent, energy saving, environmental protection, freevilled", combined with the actual situation and intelligent power grid construction requirements in combination with my country's distribution network. Secondary integration technology, developing production of independent intellectual property, domestic first intelligent permanent magnet (spring) vacuum switching equipment, integral, control, protection, communication and other functions, high intelligence. This product applies to power systems of 50Hz, 12KV, 24KV, 40.5KV, widely used in industrial and civil cable ring networks and power-on-end projects, and is the preferred equipment to ensure power grid safety, reliable, economical and efficient operation.
Model Description
Note: For more configuration, please contact us.
Use environment
Name | unit | Environmental value | |
Amazing air temperature | Maximum temperature | ℃ | +50 |
Minimum temperature | --40 | ||
Maximum temperature difference | K | 30 | |
altitude | m | ≤5000 | |
Solar radiation intensity | W / cm2 | 0.1 | |
Contamination | Ⅳ | ||
Ice thickness | mm | 10 | |
humidity | Daily relative humidity average | % | ≤100 |
Monthly relative humidity average | ≤95 | ||
Tolerate earthquake | 度 | ≤8 |
Note: Environmental parameters are exceeded in the previous table, please contact us.
Product features
Protective function | The fault current can be automatically identified, realizing the transient current speed, time-limited current speed, timing overcurrent, directional overflow, overvoltage, undercarrons, and cool load start suppression, cold load start suppression break. |
Measurement function | It can measure the three-phase current, three-phase voltage, active power, reactive power, active power, reactive power, peak / valley, power factor and frequency. |
control function | The local operation and distant control can be realized, and the fault location of the line can be automatically implemented, fault isolation and quickly restore non-fault line power supply, realize the low frequency automatic load, automatic capacitor automatic and related control functions. |
Data recording function | Information such as operation, operation, and failure can be automatically recorded. |
Intelligent function | On-line integrated analysis of the grid parameters, online monitoring of the performance parameters of the circuit breaker, online programming, can cooperate with the main station of the distribution network, implement remote control management of switching equipment, realize local, distant or hierarchical control Automation system function. |
Rated voltage | KV | 12 | 24 | 40.5 |
Rated current | A | 630/1250 | 630/1250 | 1600 |
Rated frequency | Hz | 50 | ||
Rated short (1min) power frequency tolerance voltage (on ground / broken) | KV | 42/48 | 65/79 | 95 |
Rated lightning impact tolerance voltage (on ground / broken) | KV | 75/85 | 125/145 | 185 |
Rated short circuit opening current | ka | 20/25 | 25 | 25 |
Rated short-circuitry current (peak) | ka | 50/63 | 63 | 63 |
Rated short-term resistance (4S) | ka | 20/25 | 63 | 63 |
Rated peak tolerance | ka | 50/63 | 63 | 63 |
Rated short-circuit current break | 次 | 30 | ||
Operating agency | Permanent magnet / spring | |||
Vacuum circuit breaker mechanical life | 次 | 1000 (30000 permanent magnet) | ||
Life of isolation / ground switch | 次 | 3000 | ||
Enclosure rating | IP4X | |||
Circuit breaker rated operation order | O-0.3S-CO-180S-CO |
Note: Technical parameters exceed the scope of the previous table, please contact us
Rated voltage | KV | 12 | 24 | 40.5 |
Rated current | A | 630/1250 | 630/1250 | 1600 |
Rated frequency | Hz | 50 | ||
Rated short (1min) power frequency tolerance voltage (on ground / broken) | KV | 42/48 | 65/79 | 95 |
Rated lightning impact tolerance voltage (on ground / broken) | KV | 75/85 | 125/145 | 185 |
Rated short circuit opening current | ka | 20/25 | 25 | 25 |
Rated short-circuitry current (peak) | ka | 50/63 | 63 | 63 |
Rated short-term resistance (4S) | ka | 20/25 | 63 | 63 |
Rated peak tolerance | ka | 50/63 | 63 | 63 |
Rated short-circuit current break | 次 | 30 | ||
Operating agency | Permanent magnet / spring | |||
Vacuum circuit breaker mechanical life | 次 | 1000 (30000 permanent magnet) | ||
Life of isolation / ground switch | 次 | 3000 | ||
Enclosure rating | IP4X | |||
Circuit breaker rated operation order | O-0.3S-CO-180S-CO |
Note: Technical parameters exceed the scope of the previous table, please contact us
The outdoor hydrophobic epoxy resin is used as an insulating material, with a life of more than 40 years, vacuum arc, solid insulation, oilless, no sf6No environmental pollution, no explosion and gas leaks, meet environmental requirements. |
Fully sealed waterproof design, high voltage conductor is not exposed, especially for humid and flooded regions, can be reliably powered in wet and water. |
The operating mechanism can select a permanent magnet operating mechanism or a spring operating mechanism according to user habits and actual needs. |
Isolation, ground switch and circuit breaker integrated design, compact structure and have a sound mechanical and electrical interlock design, which can effectively prevent errors. |
A rapid algorithm with national patent technology (patent number: ZL200720037710.7) can be used, so that the circuit breaker has a rapid breaking capability, and it can quickly isolate the fault line. Take 10kV permanent magnetite network cabinet as an example from detection failure to the circuit breaker. The fault line time is less than 25 ms, which can effectively avoid the problem of cross-level trip. |
A single-phase grounding protection system with national patent technology (patent number: ZL201020178325.6) can be used, and there is no need to increase the configuration of online judgment on single-phase ground failure of small current grounding systems, and give a alarm or trip operation according to the set value. . |
It is equipped with a complete charge display device and a reliable switch position indication. |
Modular design, can be extended as needed. |
Compact compact, small size, light weight, convenient installation. |
Isolation of the fracture visual, in line with safety standards. |
The temperature measurement and temperature correction technique is used, so that the switching equipment can be reliable and stable under different environmental conditions in the country. |
Note: For other features, please contact us
The outdoor hydrophobic epoxy resin is used as an insulating material, with a life of more than 40 years, vacuum arc, solid insulation, oilless, no sf6No environmental pollution, no explosion and gas leaks, meet environmental requirements. |
Fully sealed waterproof design, high voltage conductor is not exposed, especially for humid and flooded regions, can be reliably powered in wet and water. |
The operating mechanism can select a permanent magnet operating mechanism or a spring operating mechanism according to user habits and actual needs. |
Isolation, ground switch and circuit breaker integrated design, compact structure and have a sound mechanical and electrical interlock design, which can effectively prevent errors. |
A rapid algorithm with national patent technology (patent number: ZL200720037710.7) can be used, so that the circuit breaker has a rapid breaking capability, and it can quickly isolate the fault line. Take 10kV permanent magnetite network cabinet as an example from detection failure to the circuit breaker. The fault line time is less than 25 ms, which can effectively avoid the problem of cross-level trip. |
A single-phase grounding protection system with national patent technology (patent number: ZL201020178325.6) can be used, and there is no need to increase the configuration of online judgment on single-phase ground failure of small current grounding systems, and give a alarm or trip operation according to the set value. . |
It is equipped with a complete charge display device and a reliable switch position indication. |
Modular design, can be extended as needed. |
Compact compact, small size, light weight, convenient installation. |
Isolation of the fracture visual, in line with safety standards. |
The temperature measurement and temperature correction technique is used, so that the switching equipment can be reliable and stable under different environmental conditions in the country. |
Note: For other features, please contact us